Air purifier Comparison Chart
Model

Hunter Permalife 30547

Whirlpool AP51030K

Blueair 503

Rabbit Air MinusA2 Asthma and Allergy Friendly™ Air Purifier

Austin Air Allergy Machine (HM405)

dimensions 24H x 17W x 12D 26H x 20W x 13D 26H x 20W x 13D 20H x 21.4W x 7D 23H x 14.5W x 14.5D
Web page http://www.hunterfan.com/Products/Air-Purifiers/PermaLife-30547/ http://usa.blueair.com/air-purifiers/500-series/blueair-503 http://usa.blueair.com/air-purifiers/500-series/blueair-503  http://www.rabbitair.com/minusa2-asthma-and-allergy-friendly-edition-air-purifier.aspx  http://austinair.com/products/hega-series/
Cost $260.00 $300.00 $600.00 $590.00  $575.00
Replacement filter Annual cost
$180
$212
$233
 $75   $250
Warranty
5 Years
 1 year (5 year extended)  5 Years 5 years on all parts and labor.
Overall score (Out of 100)  73 Very Good 74 Very Good  67 Very Good
Dust/pollen/smoke removal (high)
Dust/pollen/smoke removal (low)
Noise (high speed)
Noise (low speed)
Room size
510 SF
Large
580
 700  1500 cu ft
Air Flow  90cfm414 cfm  Speed 1 – 58 CFM
Speed 2 – 80 CFM
Speed 3 – 112 CFM
Speed 4 – 159 CFM
Speed 5 – 218 CFM
 400 cfm of air is circulated on the highest setting
CADR:Clean Air Delivery Rate pollen: 330dust: 330

smoke: 330

 Pollen: 375
Dust: 375
Smoke: 375
Pollen: 208
Dust: 200
Smoke: 193
 Meets HEPA standards, trapping 99.97% of all particulates larger than 0.3 microns and 95% of particles as small as 0.1 micro
 Noise Level (Decibels) 32 – 66  Speed 1 – 25.6 dBA
Speed 2 – 31.1 dBA
Speed 3 – 37.4 dBA
Speed 4 – 44.5 dBA
Speed 5 – 51.3 dBA
 Power Consumption  Energy Star rated 35 to 120  watts(Energy Star) 6 to 61 watts
(Energy Star)
 115W
 Ozone Emissions No. The most stringent government standards for indoor ozone are those of the Food and Drug Administration for indoor medical devices, which specify that ozone output be no more than .05 ppm. In a closed test room with the Blueair 501 in operation, probes measured ozone levels at .003 ppm-a tiny fraction of the amount deemed hazardous to human health. Our design safeguards against excessive ozone production, and then removes ambient ozone particles from the air.Specifically, the Blueair 501 system was subjected to the Ozone Test outlined in section 37 of the Electrostatic Air Cleaner Standard, UL 867. The unit was positioned in the center of a closed 100 square foot room. The unit’s ozone output was tested continuously throughout 24 hours of normal operation. *Zero ozone emission with negative ion generator turns off. An amount of 0.002 ppm (parts-per-million) was recorded at low fan speed with negative ionizer turned on. That is 25 times less than the 0.05 ppm maximum ozone concentration safety standard set forth by the California Air Resource Board.  ZERO